Fiberglass Technologies, Inc.

1610 Hanford Street * Levittown, PA 19057 * Phone: 215-943-4567 * Email: info@fiberglasstechnologies.com    

News

:: 7/9/2010
New Columns

:: 7/6/2010
New Project Pictures

Specifications

See Architectural Specs
See Flame-Retardant Polyester Resins
Flammability Test Data ::
See Typical Liquid Properties
See Typical Mechanical Properties

FLAMMABILITY TEST DATA

 

      FT 8815 with 1.7% Antimony Trioxide

      3 ply, 1 . 5 oz. mat Laminates

  • Flame Spread Index 15 (Class1)

  • Smoke Development Index 940

 

      FT 8815 with 3% Antimony Trioxide

      3 ply, 1. 5 oz mat Laminates

  • FT 8815 with 0% Antimony Trioxide
  • 3 ply, 1. 5 oz. mat Laminates

 ASTM E-84

Tunnel Test

  • Flame Spread Index 15 (Class1)

  • Smoke Development Index 695

  • Flame Spread 30 (Class11)

ASTM D635

  • Average Time of Burning (ATB) 1 second
  • Average Extent of Burning (AEB) 8.2mm
  • Average Time of Burning (ATB) 3.9 seconds
  • Average Extent of Burning (AEB) 7.8 mm
UL94

  • V-O rating

  • 5V rating
 
FMVSS032

  • Passed-Laminate did not ignite

ASTM

D1929-91a

  • Self-ignition temperature 393˚C (740˚F)

  • Flash-ignition temperature 372˚C (702˚F)

  • Self-ignition temperature 432˚C (810˚F)

  • Flash-ignition temperature 378˚C (712˚F)

FAR 853

  • Passed horizontal and vertical test

 

FAR 532

  • Passed

  • Passed
      Filled FT 8815 Formula #1      Filled FT 8815 Formula #2
 

      FT 8815, parts                                57.5

      Styrene Monomer                             2.5

      Alum. Trihydrate, parts                    40.0

     FT 8815, parts                                45.5

     Styrene Monomer                             4.5

     Alum. Trihydrate, parts                    50.0

Bombardier

SMP-1 Smoke

Toxicity

 

  • Passed

 

  • Passed

 

FAR 853

 
  • Passed horizontal and vertical

FAR 532

 

  • Passed

 

ASTM E-84

Tunnel Test

 
  • Flame Spread Index 20
  • Smoke Developed Index 375

ASTM E162

Tunnel Test

 

  • Flame Spread 10

 

  • Flame Spread 10

 

NBS Smoke

Chamber (ASTM E-662)

    Test Time

     Specific Optical

     Density (Ds)

       Test Time

    Specific Optical

    Density (Ds)

  • 1. 5 min

  • 4.0 min

  • 5

  • 160

  • 1. 5 min

  • 4. 0 min

  • 1

  • 94